<sub id="a1w4h"></sub>
    <s id="a1w4h"><var id="a1w4h"></var></s>
  • <dfn id="a1w4h"><strike id="a1w4h"></strike></dfn>

  • <cite id="a1w4h"><rp id="a1w4h"><form id="a1w4h"></form></rp></cite>
    蜜臀av中文人妻系列,国产精品三级在线观看不卡 ,99久久国产综合精品女图图等你 ,国产欧美一区二区精品久久久,国产91麻豆免费观看,一区二区中文字幕久久,国产成人免费高清在线观看,熟妇的奶头又大又长奶水视频
    歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!

    產品名稱:類固醇激素校準品

    產品型號:72038 72039

    產品報價:

    產品特點:

    供應商:祥生興業規格:7x3ml(lyoph

    免費咨詢:13681184382

    發郵件給我們:702140183@qq.com

    分享到:

    72038 72039類固醇激素校準品的詳細資料:

    溫馨提示:僅用于科研,不可用于臨床治療

    • 供應商:

      祥生興業

    • 規格:

      7 x 3 ml (lyoph.)


      72038  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1


      Order no.: 72038
      • 11-Deoxycortisol
      • 21-Deoxycortisol
      • Aldosterone
      • Corticosterone
      • Cortisol
      • Cortisone

      MassChrom® Steroids in Serum/Plasma - LC-MS/MS

      DESCRIPTION

      6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
      For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

      These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
      These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

      TECHNICAL DATA

      Method of Analysis

      LC-MS/MS

      Content

      7 x 3 ml (lyoph.)

      Parameter

      11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone

      Concentrations

      Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

      Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
      Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
      Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
      Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
      Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
      11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
      21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
       
      n.d. = not determined, analytes under LOQ

      Reconstitution

      Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

      Storage conditions

      Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

       

      72039  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2


      Order no.: 72039
      • 11-Deoxycorticosterone
      • 17-OH-progesterone
      • Androstenedione
      • Dehydroepiandrosterone (DHEA)
      • Dehydroepiandrosterone sulfate (DHEA-S)
      • Dihydrotestosterone (DHT)
      • Estradiol
      • Progesterone
      • Testosterone

      MassChrom® Steroids in Serum/Plasma - LC-MS/MS

      DESCRIPTION

      6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
      For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

      These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
      These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

      TECHNICAL DATA

      Method of Analysis

      LC-MS/MS

      Content

      7 x 3 ml (lyoph.)

      Parameter

      11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, Testosterone

      Concentrations

      Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

      Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
      Androstenedione µg/l 0.202 0.408 0.820 1.54 5.09 15.3 n.d. (< 0.020)
      11-Deoxycorticosterone µg/l 0.049 0.098 0.146 0.288 0.721 2.80 n.d. (< 0.023)
      DHEA µg/l 1.04 5.25 10.3 15.6 30.7 60.7 n.d. (< 0.229)
      DHEAS µg/l 117 558 1097 2066 3949 5887 n.d. (< 24.4)
      Dihydrotestosterone µg/l 0.061 0.111 0.257 0.501 0.942 1.50 n.d. (< 0.042)
      Estradiol µg/l 0.043 0.105 0.260 0.530 1.59

      5.33

      n.d. (< 0.026)
      17-Hydroxyprogesterone µg/l 0.097 0.498 1.01 2.00 3.98 15.0 n.d. (< 0.040)
      Progesterone µg/l 0.180 0.805 2.11 5.27 10.3 26.0 n.d. (< 0.030)
      Testosterone µg/l 0.055 0.250 0.982 2.94 5.82 11.6 n.d. (< 0.005)
       n.d. = not determined (< LOQ)

      Reconstitution

      Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

      Storage conditions

      Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

       

    溫馨提示:不可用于臨床治療。
     相關同類產品:

    留言框

    • 產品:

    • 您的單位:

    • 您的姓名:

    • 聯系電話:

    • 常用郵箱:

    • 省份:

    • 詳細地址:

    • 補充說明:

    • 驗證碼:

      請輸入計算結果(填寫阿拉伯數字),如:三加四=7

    版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:129731  sitemap.xml